ESX-TC3G
1 Febbraio 2017Expansion boards
10 Febbraio 2017OPUS A3 ECO BASIC
OPUS A3 ECO BASIC
All Basic Needs Covered
A lot of technology – at a low investment cost. This slogan fittingly describes the OPUS A3e. This full-value operator console features a 4.3” screen with 480 x 272 pixels and is optionally available with a touchscreen display. A further plus point of the OPUSA3e is its weight: less than 1kg.
All’interno è un potente e affidabile 32-bit, 532 MHz, con opzione di memoria che va da un minimo di 512 MB, fino a 1 GB. Dotato di un LED multicolore, di 4 ingressi analogici o digitali, di 2 porte CANBUS e di un’interfaccia USB 2,0 a piena velocità, questa unità a basso costo non è priva di funzionalità. Opus A3E: alte prestazioni ad un prezzo di base.
Allarme Acustico
Per assicurare un monitoraggio affidabile, la versione full line dell’Opus A3E è dotata di un allarme acustico con un’uscita fino a 65 dBA. Questo lo rende particolarmente adatto come unità di parametrizzazione e utilizza il sistema operativo di fiducia Linux embedded.
Potete contare su di esso: l’Opus A3E offre il miglior rapporto prezzo-prestazioni disponibile sul mercato nella sua categoria.
Dichiarazioni
OPUS A3 ECO BASIC è un prodotto di
Topcon Electronics
Tutti i diritti sono riservati.
Specifications
Hardware | ||
---|---|---|
Processor | Freescale I.MX35®, 532 MHz | |
Mass storage | 512 MByte (approx. 450 MB for customer use) | |
RAM | 128 MByte | |
RTC | Buffered by battery | |
Temperature range | Operating: -30..+75°C Storage: -40..+85°C | |
Electrical | ||
Display | TFT Color Graphic LCD with LED backlight | |
Resolution | 480 x 272 px (WQVGA), 15:9 | |
Colors | 16.7 Mio. | |
Brightness | typ. 400 cd/m² | |
Contrast Ratio | typ. 400:1 | |
Size | 4.3”, 95 mm (W) x 53 mm (H) | |
Touch | Analog resistive | |
Indicators and sensors | • Light sensor • 1 Multicolor-LED | |
Power requirements | 9 … 36 V DC | Short circuit protection. Overvoltage resistance: 48V for max. 2 minutes. Inverse polarity protection: up to -48 V DC for max. 5 minutes |
Interfaces | ||
CAN bus | 2 x CAN-Interfaces according to ISO 1 1898 | CAN specification 2.0 B active, up to 1 Mbit/s (default 250 Kbit/s, 500 Kbit/s, 750 Kbit/s and 1 Mbit/s) |
RS 232 | 1 x RS232-Interface | Type: EIA232 (only RxD, TxD, GND), Speed: max. 115 Kbps |
USB | 1 x HOST 2.0 | Main connector: 1 x Full speed |
Buzzer | No | |
Connectors | ||
Main | T yco-AMP 1437288-6 | Mating connector (customer) T yco-AMP 3-1437290-7 Mating crimp contact (customer) T yco-AMP 3-1447221-4 |
Software | ||
Operating System | Linux, kernel 2.6.28 | |
Application Programming | Motronica M- V ision | • Optional:Codesys- T ools (3.5) • Optional: ISO-VT • Optional: C/C++ • Optional: W achendor f f Projektor T ool |
Testing and verification | ||
CE | EU Directive 2004/108/EC (EMC) according to • EN 12895: Industrial T rucks – Electromagnetic compatibility • EN 13309: Construction machinery – Electromagnetic compatibility of machines with internal electrical power supply • EN ISO 14982: Agricultural and forestry machinery - Electromagnetic compatibility - T est methods and acceptance criteria | |
E1 - Type approval | EU Directive ECE R 10.4 | |
Protection Level (IP Code) | IP 6k5 and 6k7according to ISO 20653: Road V ehicles – Degrees of protection (IP-Code) – Protection of electrical equipment against foreign objects, water and access | |
Electrical | 12 and 24 V -Systems according to ISO 16750-2: Road V ehicles – Environmental conditions and testing for electrical and electronic equipment – Electrical loads | ISO 15003: Agricultural Engineering – Electrical and electronic equipment – T esting resistance to environmental conditions |
Mechanical | • ISO 16750-3: Road V ehicles – Environmental conditions and testing for electrical and electronic equipment – Mechanical loads, Code L • ISO 15003: Agricultural Engineering – Electrical and electronic equipment – T esting resistance to environmental conditions • Mechanical Shock: Level 2 • Random V ibration: Level 2 • Sinusoidal V ibration: Level 2 | |
Climate | • ISO 16750-4: Road V ehicles – Environmental conditions and testing for electrical and electronic equipment – Climatic Loads • Operating T emperature Range: -30 … +65°C • Storage T emperature Range: -40 … +85°C • ISO 15003: Agricultural Engineering – Electrical and electronic equipment – T esting resistance to environmental conditions |
Tools
Cables
Connectors
Mounting Kits
ESX-TC3G
1 Febbraio 2017Expansion boards
10 Febbraio 2017OPUS A3 ECO BASIC
OPUS A3 ECO BASIC
All Basic Needs Covered
A lot of technology – at a low investment cost. This slogan fittingly describes the OPUS A3e. This full-value operator console features a 4.3” screen with 480 x 272 pixels and is optionally available with a touchscreen display. A further plus point of the OPUSA3e is its weight: less than 1kg.
Inside is a powerful and reliable 32-bit, 532 MHz processor, with memory option ranging from a minimum of 512 MB, up to 1 GB. Equipped with a multi-color LED, 4 analogue or digital inputs, 2 CANbus ports and a full-speed USB 2.0 interface, this low-cost unit is not lacking in functionality. The OPUS A3e: high performance at an entry-level price.
Acoustic Alarm
To assure reliable monitoring, the full line version of the OPUS A3e features an acoustic alarm with an output of up to 65 dBA. This makes it particularly suitable as a parametrisation unit, and it uses the trusted Embedded Linux operating system.
You can count on it: the OPUS A3e offers the best price-to-performance ratio available on the market in its class.
Statements
OPUS A3 ECO BASIC is a product of
Topcon Electronics
All rights are reserved.
Specifications
Hardware | ||
---|---|---|
Processor | Freescale I.MX35®, 532 MHz | |
Mass storage | 512 MByte (approx. 450 MB for customer use) | |
RAM | 128 MByte | |
RTC | Buffered by battery | |
Temperature range | Operating: -30..+75°C Storage: -40..+85°C | |
Electrical | ||
Display | TFT Color Graphic LCD with LED backlight | |
Resolution | 480 x 272 px (WQVGA), 15:9 | |
Colors | 16.7 Mio. | |
Brightness | typ. 400 cd/m² | |
Contrast Ratio | typ. 400:1 | |
Size | 4.3”, 95 mm (W) x 53 mm (H) | |
Touch | Analog resistive | |
Indicators and sensors | • Light sensor • 1 Multicolor-LED | |
Power requirements | 9 … 36 V DC | Short circuit protection. Overvoltage resistance: 48V for max. 2 minutes. Inverse polarity protection: up to -48 V DC for max. 5 minutes |
Interfaces | ||
CAN bus | 2 x CAN-Interfaces according to ISO 1 1898 | CAN specification 2.0 B active, up to 1 Mbit/s (default 250 Kbit/s, 500 Kbit/s, 750 Kbit/s and 1 Mbit/s) |
RS 232 | 1 x RS232-Interface | Type: EIA232 (only RxD, TxD, GND), Speed: max. 115 Kbps |
USB | 1 x HOST 2.0 | Main connector: 1 x Full speed |
Buzzer | No | |
Connectors | ||
Main | T yco-AMP 1437288-6 | Mating connector (customer) T yco-AMP 3-1437290-7 Mating crimp contact (customer) T yco-AMP 3-1447221-4 |
Software | ||
Operating System | Linux, kernel 2.6.28 | |
Application Programming | Motronica M- V ision | • Optional:Codesys- T ools (3.5) • Optional: ISO-VT • Optional: C/C++ • Optional: W achendor f f Projektor T ool |
Testing and verification | ||
CE | EU Directive 2004/108/EC (EMC) according to • EN 12895: Industrial T rucks – Electromagnetic compatibility • EN 13309: Construction machinery – Electromagnetic compatibility of machines with internal electrical power supply • EN ISO 14982: Agricultural and forestry machinery - Electromagnetic compatibility - T est methods and acceptance criteria | |
E1 - Type approval | EU Directive ECE R 10.4 | |
Protection Level (IP Code) | IP 6k5 and 6k7according to ISO 20653: Road V ehicles – Degrees of protection (IP-Code) – Protection of electrical equipment against foreign objects, water and access | |
Electrical | 12 and 24 V -Systems according to ISO 16750-2: Road V ehicles – Environmental conditions and testing for electrical and electronic equipment – Electrical loads | ISO 15003: Agricultural Engineering – Electrical and electronic equipment – T esting resistance to environmental conditions |
Mechanical | • ISO 16750-3: Road V ehicles – Environmental conditions and testing for electrical and electronic equipment – Mechanical loads, Code L • ISO 15003: Agricultural Engineering – Electrical and electronic equipment – T esting resistance to environmental conditions • Mechanical Shock: Level 2 • Random V ibration: Level 2 • Sinusoidal V ibration: Level 2 | |
Climate | • ISO 16750-4: Road V ehicles – Environmental conditions and testing for electrical and electronic equipment – Climatic Loads • Operating T emperature Range: -30 … +65°C • Storage T emperature Range: -40 … +85°C • ISO 15003: Agricultural Engineering – Electrical and electronic equipment – T esting resistance to environmental conditions |
Tools
Cables
Connectors
Mounting Kits
Code 1130207006000 OPUS A3 EB 4,3″ CFG STD
Code 1141202001000 DISPLAY OPUS A3 ECO BASIC 4,3″ CODESYS
Code 1130207007300 DISPLAY OPUS A3 ECO BASIC 4,3″ TOUCH CFG STD
Code 1141204000400 DISPLAY OPUS A3 ECO BASIC 4,3″ TOUCH CODESYS
Code 1141204003000 DISPLAY OPUS A3 ECO BASIC 4,3″ TOUCH ISO-VT