Technology for Convenience
The OPUS A6e is the fi rst choice for complex HMI (Human Interface) which rely on the processing of a wide range of information. This unit features a bright, high-resolution display with a great picture – and therefore offers complete ease of use under all operating conditions. With an optimised size of 7” and a 800 x 480 pixel resolution, everything the operator needs is perfectly readable.
The large 2 GB of memory, combined with the 32-bit, 800 MHz processor, is ideally suited to demanding applications. The device can be orientated either horizontally or vertically and we can supply it in either standalone or dashboard options.
Integrated Camera Input
A built-in camera input allows you to easily connect an OPUS camera. Further features of the OPUS A6e are two CANbus ports and one Ethernet port. The OPUS A6e can also be fi tted with a PTC touchscreen and two additional camera inputs as optional extras.
Statements
OPUS A6 ECO BASIC (G2) is a product of
Topcon Electronics
All rights are reserved.
Specifications
Hardware | ||
---|---|---|
Processor | Freescale I.MX6®, solo 800 MHz | |
Mass storage | 2 GByte | |
RAM | 256 Mbyte | |
RTC | Buffered by gold cap | |
Temperature range | Operating: -30..+65°C Storage: -40..+85°C | |
Electrical | ||
Display | TFT Color Graphic LCD with LED backlight | |
Resolution | 800x480 px (WVGA), 15:9 | |
Colors | 262k | |
Brightness | typ. 400 cd/m² | |
Contrast Ratio | typ. 500:1 | |
Size | 7”, 152 mm (W) x 91 mm (H) | |
Touch | PCT | |
Power requirements | System supplied through terminal 30 (battery +, see pinout) and 31 (battery -, see pinout). Terminal 15 (ignition) to be used to switch on/off. 9 … 36 V DC | Short circuit protection. Overvoltage resistance: 48 V for max. 2 minutes. Inverse polarity protection: up to -48 V DC for max. 5 minutes |
Interfaces | ||
CAN bus | 2 x CAN-Interfaces according to ISO 1 1898 | CAN specification 2.0 B active, up to 1 Mbit/s (default 250 Kbit/s, 500 Kbit/s, 750 Kbit/s and 1 Mbit/s) |
RS 232 | 1 x RS232-Interface | Type: EIA232 (only RxD, TxD, GND), Speed: max. 115 Kbps |
USB | 1 x HOST 2.0 | Main connector: 1 x Full speed |
Ethernet | 1 x 10/100 Mbit/s Base T | |
Buzzer | Yes | 80 dB @ 1kHz in 1 m distance |
Video-Interface | • Inputs: 1x analog • Vss 1 V • Camera supply: 12 V DC • Output: 1x camera control output (open drain) on each interface for special functionality (mirror, shutter, heating etc.), Ampacity: 300mA |
|
Connectors | ||
Main | T yco-AMP 1437288-6 | Mating connector (customer) T yco-AMP 3-1437290-7 Mating crimp contact (customer) T yco-AMP 3-1447221-4 |
V ideo | M12 round connecto r , female, 5-pole, B-coded, acc. to EN 61076-2-101 | Recommended mating connector type according to IEC 61076-2-10: MM 005-Gx1-Bx A, C, I, P, R or S-type |
Ethernet | M12 round connecto r , female, 4-pole, D-coded acc. to EN 61076-2-101 | Recommended mating connector type according to IEC 61076-2-10: MM 004-Gx1-Dx A, C, I, P, R or S-type |
Software | ||
Operating System | Linux, Kernel 3.0.0 or higher | |
Application Programming | Motronica M- V ision | OPUS Projektor • Optional: Codesys-Tools (3.5) • Optional: ISO-VT • Optional: C/C++ |
Testing and verification | ||
CE-Compliance | EU Directive 2014/30/EU (EMC) according to • EN 12895: Industrial Trucks – Electromagnetic compatibility • EN 13309: Construction machinery – Electro-magnetic compatibility of machines with internal electrical power supply • EN ISO 14982: Agricultural and forestry machinery - Electromagnetic compatibility - Test methods and acceptance criteria |
|
E1 - Type approval | EU Directive ECE R 10.4 (Dec 2013) | |
Protection Level (IP Code) | IP 65 and IP 66 according to ISO 20653: Road Vehicles – Degrees of protection (IP-Code) – Protection of electrical equipment against foreign objects, water and access |
|
Electrical | 12 and 24V-Systems according to ISO 16750-2: Road Vehicles – Environmental conditions and testing for electrical and electronic equipment – Electrical loads | ISO 15003: Agricultural Engineering – Electrical and electronic equipment – Testing resistance to environmental conditions |
Mechanical | • ISO 16750-3: Road Vehicles – Environmental conditions and testing for electrical and electronic equipment – Mechanical loads, Code L • ISO 15003: Agricultural Engineering – Electrical and electronic equipment – Testing resistance to environmental conditions • Mechanical Shock: Level 2 • Random Vibration: Level 2 • Sinusoidal Vibration: Level 2 |
|
Climate | • ISO 16750-4: Road Vehicles – Environmental conditions and testing for electrical and electronic equipment – Climatic Loads • Operating Temperature Range: -30 … +65°C • Storage Temperature Range: -40 … +85°C • ISO 15003: Agricultural Engineering – Electrical and electronic equipment – Testing resistance to environmental conditions |
Tools
Cables
Connectors
Mounting Kits
Code 1130207009500 OPUS A6 EB 7″ G2 CFG STD
Code 1130207005600 DISPLAY OPUS A6 ECO BASIC 7″ CFG STD
Code 1141202001400 DISPLAY OPUS A6 ECO BASIC 7″ CODESYS
Code 1141204003400 DISPLAY OPUS A6 ECO BASIC 7″ ISO-VT
Code 1130207008300 DISPLAY OPUS A6 ECO BASIC 7″ TOUCH CFG STD
Code 1141206000600 DISPLAY OPUS A6 ECO BASIC 7″ TOUCH CODESYS
Code 1141206001200 DISPLAY OPUS A6 ECO BASIC 7″ TOUCH ISO-VT