Products

OPUS A8 ECO BASIC
14 February 2017
OPUS A8 STANDARD BASIC
15 February 2017
Show all
1130207009100

OPUS A8 ECO FULL


OPUS A8 ECO FULL
Communicative Competencence

In the OPUS A8e, we have combined the most brilliant technology into a single unit – with maximum performance and a sophisticated design. Unlike the OPUS A8 Standard, the OPUS A8e is operated entirely without keys.

This is achieved through a high-quality touch panel with an analog resistive glass surface. A distinguishing feature of the OPUS A8e is its scalable process architecture. Its high performance enables the device to simultaneously display all safety factors on the video raster screen. The OPUS A8e’s great look is thanks to an extravagantly designed aluminium casing.
The OPUS A8e is therefore the ideal device for demanding users and applications.

Two CANbus Ports
The high-performance, 32-bit, 532 MHz processor and the memory capacity of either 512 MB or 1 GB of RAM plus 128 or 256 MB of DDR2 make the OPUS A6s a powerful heavyweight. Fitted with two CANbus ports, it leaves no wish unfulfilled. A front-mounted, high-speed USB port and 3 camera inputs can also be included as optional extras. Problem-free functionality is assured by the trusted Embedded Linux operating system.

Statements
OPUS A8 ECO FULL is a product of
Topcon Electronics

All rights are reserved.

Specifications

Hardware
ProcessorFreescale I.MX6®, quad core, 1 GHz
Mass storage8 GByte
RAM1024 Mbyte
RTCBuffered by gold cup
Temperature rangeOperating: -30..+65°C Storage: -40..+85°C
Electrical
DisplayTFT Color Graphic LCD with LED backlight
Resolution1280 x 800 px (WXGA), 16:10
Colors24 bit
Brightnesstyp. 400 cd/m²
Contrast Ratiotyp. 1,000:1
Size12.1“, 261 mm (W) x 163 mm (H)
TouchPCT
Indicators and sensors• Light sensor
• 1 Multicolor-LED
• Status-LED ’ s
Power requirements9 … 36 V DCShort circuit protection.
Over-voltage resistance: 48 V for max. 5 minutes. Inverse polarity protection up to -48 V DC for max. 5 minutes
Interfaces
CAN bus2 x CAN-Interfaces according to ISO 1 1898CAN specification 2.0 B active,
up to 1 Mbit/s (default 250 Kbit/s, 500 Kbit/s, 750 Kbit/s and 1 Mbit/s)
RS 2321 x RS232-InterfaceType: EIA232 (only RxD, TxD, GND), Speed: max. 115 Kbps
USBMain connector: 1 x High speed
Ethernet1 x 10/100 Mbit/s Base T
BuzzerNo
Inputs4 configurable analog/digital inputsInput impedance: > 3k Ohm Resolution: 10 bit (1028 digits, 1 digit = 1 1,7 mV) Input range: 0...12 V ,4-20mA,0-20mA
Max protectable input voltage: 36 V DC Short circuit protection
Frequency: Max. signal frequency 50 Hz
Outputs3 digital outputsShort circuit protection: Up to 36 V
Imax 300 mA open drain at 12 V RDS,on < 1 Ohm RDS,o f f > 100 kOhm
Connectors
MainTyco-AMP 3-1437290-7
V ideoM12 round connecto r , female, 5-pole, B-coded, acc. to EN 61076-2-101
EthernetM12 round connecto r , female, 4-pole, D-coded acc. to EN 61076-2-101
Software
Operating SystemLinux 3.x
Application ProgrammingMotronica M- V ision• Optional:Codesys- T ools (3.5)
• Optional: ISO-VT
• Optional: C/C++
• Optional: W achendor f f Projektor T ool
Testing and verification
CEEU Directive 2014/30/EU (EMC) according to
• EN 12895: Industrial T rucks – Electromagnetic compatibility
• EN 13309: Construction machinery – Electromagnetic compatibility of machines with internal electrical power supply
• EN ISO 14982: Agricultural and forestry machinery - Electromagnetic compatibility - T est methods and acceptance criteria
E1 - Type approvalEU Directive ECE R 10
Protection Level (IP Code)IP 6k5 according to ISO 20653: Road V ehicles – Degrees of protection (IP-Code) – Protection of electrical equipment against foreign objects, water and access
Electrical12 and 24 V -Systems according to ISO 16750-2: Road V ehicles – Environmental conditions and testing for electrical and electronic equipment – Electrical loadsISO 15003: Agricultural Engineering – Electrical and electronic equipment – T esting resistance to environmental conditions
Mechanical• ISO 16750-3: Road V ehicles – Environmental
conditions and testing for electrical and electronic equipment – Mechanical loads, Code L
• ISO 15003: Agricultural Engineering – Electrical and electronic equipment – T esting resistance to environmental conditions
• Mechanical Shock: Level 2
• Random V ibration: Level 2
• Sinusoidal V ibration: Level 2
Climate• ISO 16750-4: Road V ehicles – Environmental conditions and testing for electrical and electronic equipment – Climatic Loads
• Operating T emperature Range: -30 … +65°C
• Storage T emperature Range: -40 … +85°C
• ISO 15003: Agricultural Engineering – Electrical and electronic equipment – T esting resistance to environmental conditions

Code 1130207009300 – DISPLAY OPUS A8 ECO FULL 12,1″ CFG STD
Code 1141204002800 – DISPLAY OPUS A8 ECO FULL 12,1″ CODESYS

Code 1141204004000 – DISPLAY OPUS A8 ECO FULL 12,1″ ISO-VT